Report expires: 02/02/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Feb 02, 2026 | Feb 02, 2026 | r5540-eagle-plant-london-west-kubota-u50-5-excavator-s-n-11805 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Eagle Plant London West, Stanwell Moor, TW19 6AQ | Eagle Plant London West, Stanwell Moor, TW19 6AQ |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| R5540 Kubota U50-5 Excavator s/n 11805 | As per manufacturer’s specifications | Feb 02, 2026 | 2022 | 27/01/2025 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|