Report expires: 12/01/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Jan 12, 2026 | Jan 12, 2026 | r5557-eagle-plant-london-west-jcb-535-95-telehandler-s-n-3237145-reg-wm72-jsv |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Eagle Plant London West, Stanwell Moor, TW19 6AQ | Longcross Studios, KT16 0EE |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| R5557 JCB 535-95 Telehandler s/n JCB5ABNGEN3237145 Reg WM72 JSV | Max 3500kg | Jan 12, 2026 | 2022 | 17/01/2025 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|