Report expires:   08/03/2024  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Mar 08, 2023 Mar 08, 2023 recycling-lives-erith-still-forklift-rc42-50-s-n-b16012x00172-2

Client details

      Address of the premesis      
Recycling lives Erith Dartford DA8 2LG

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture
Still forklift EC42-50 s/nB16012X00172 Max 5000kg Mar 08, 2023 2020 N/A
Defects
No defects

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 12 months yes no


Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
BAGMA Approved Thorough Examiner
BAGMA ID: 210011893
The Loler Man - NN15 6TP