Report expires:
28/04/2024
|
Report of thorough examination of lifting equipment
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
| Last Updated |
Date of report |
Report number |
| Apr 28, 2023 |
Apr 28, 2023 |
recycling-lives-preston-linde-h30-forklift-s-n-h2x393u01593-2 |
Client details
| Address of the premesis |
| Recycling lives Preston PR2 6BX |
Equipment / Examination
| Description of the equipment |
Safe working load |
Date of exam |
Date of manufacture |
| 478 Linde H30 forklift s/n H2X393U01593 |
Max 3000kg |
Aug 14, 2026 |
2007 N/A |
N/A |
| Is this the first examination after installation? |
Has the equipment been installed correctly? |
| no |
yes |
| Was the examination carried out? |
In accordance of the examination scheme? |
In exceptional circumstances? |
| In an interval of 12 months |
no |
no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
No defects |
| Particulars of any test carried out as part of the examination? |
Full test carried out |
| Is the above a defect which is immediate danger to persons |
no |
| Is the above a defect which is not yet but could become an immediate danger to persons |
no |
| Is this equipment safe to operate? |
Yes |
| Name of person authenticating this report: |
Andrew Sands
BAGMA Approved Thorough Examiner
BAGMA ID: 210011893
The Loler Man - NN15 6TP |