Report expires: 09/09/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Sep 09, 2025 | Sep 09, 2025 | smt-volvo-excavator-ec300el-s-n-318442 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| SMT Volvo Treforest Pontypridd CF37 5YL | SMT Volvo Treforest Pontypridd CF37 5YL |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Volvo excavator EC300EL s/n VCEC300ET00318442 with miller hitch s/n GTW7TVV12310458 | As per manufacturer’s guidelines | Sep 09, 2025 | 2024 | Declaration of conformity |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|