Report expires: 07/01/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Jan 07, 2026 | Jan 07, 2026 | speakmans-construction-scania-mv70-v0y-tipper-palfinger-loader-crane-s-n-1100004576 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Speakmans construction ltd unit 8 quest park Haywood BL97JJ | Speakmans construction ltd unit 8 quest park Haywood BL97JJ |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Ycrane_spz_1 Palfinger loader crane | 1270kg@8m 2090@5m 3540kg@3m | Jan 07, 2026 | 2020 | Unknown |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|