Report expires: 10/06/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Jun 10, 2026 | Jun 10, 2026 | spitfire-engineering-ltd-mitsubishi-fd15n-forklift-s-n-f16d-68205 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Spitfire Engineering Services Ltd, Brixworth, NN6 9DS | Spitfire Engineering Services Ltd, Park Farm, Brixworth, NN6 9DS |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Mitsubishi FD15N Counterbalance FLT s/n F16D-68205 | 1350kg @ 500mm load centre | Jun 10, 2026 | 2004 | 27/06/2025 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
Rear tyres worn |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out Chain wear measured primary 0.5% secondary 0.5% Pallet fork heels 37mm/40mm |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|