Report expires:   21/06/2025  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Dec 21, 2024 Dec 21, 2024 think3-e-consortuim-material-handler-mhl331-s-n-3310110036

Client details

   Name and address of employer           Address of the premesis      
Think3e Consortuim 15-21 links road Wellingborough NN8 4EY Think3e Consortuim 15-21 links road Wellingborough NN8 4EY

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
Fuchs MHL331 material handler s/n 331010036 Max 1400kg Dec 21, 2024 1997 Unknown
Defects
See below

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 6 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

Slight Hydrolic leak


Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
The Loler Man - NN15 6TP