Report expires: 15/06/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Jun 15, 2025 | Jun 15, 2025 | think3e-consortuim-hyster-forklift-h3-0ft-s-n-p177b02726n |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Think3e Consortuim 15-21 links road Wellingborough NN8 4EY | Think3e Consortuim 15-21 links road Wellingborough NN8 4EY |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Hyster Forklift H3.0FT s/n P177B02726N | Max 2400kg | Jun 15, 2025 | 2015 | Unknown |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|