Report expires: 12/10/2025 |
Last Updated | Date of report | Report number |
---|---|---|
Apr 12, 2025 | Apr 12, 2025 | tts-77-ormet-man-basket-thompson-tree-services-s-n-ca11783 |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
Thompson tree services Ashleigh house Wirksworth DE4 4FR | Thompson tree services Ashleigh house WirksworthDE4 4FR |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
TTS 77 Ormet man basket s/n CS11784 | Max 200 kg | Apr 12, 2025 | 2022 | Unknown |
Defects None |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 6 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
No defects |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|