Report expires: 28/10/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Apr 28, 2026 | Apr 28, 2026 | veka-recycling-genie-gs-1932-mewp-s-n-gs3013c-13771 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| VEKA Recycling, Nielson Road, Wellingborough, NN8 4PE | VEKA Recycling, Nielson Road, Wellingborough, NN8 4PE |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Genie GS-1932 MEWP s/n GS3013C-13771 | Max 227kg | Apr 28, 2026 | 2013 | Unknown |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 6 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|