Report expires:   18/11/2024  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Nov 18, 2023 Nov 18, 2023 yk61-bto-baileys-skip-hire-hook-loader

Client details

   Name and address of employer           Address of the premesis      
Baileys skip hire heritage way Corby NN17 5XW Baileys skip hire heritage way Corby NN17 5XW

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
YJ61 BTO hook loader XR26S multi lift s/n 26S5514624239 Max 26000kg Nov 18, 2023 2011 Unknown
Defects
None

Is this the first examination after installation? Has the equipment been installed correctly?
yes yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 12 months yes yes

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

No defects


Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons yes
Is the above a defect which is not yet but could become an immediate danger to persons yes
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
The Loler Man - NN15 6TP